Fire connector for extinguishing fires

Fire connector for extinguishing fires
Fire connector for extinguishing fires

We have the only connector in the world that is used in fire trucks and fire equipment. We easily understand that mixed use of connectors is not allowed in fire engines. Strict standardization guarantees that the hoses always fit each other and the fire equipment when extinguishing a fire. Many companies could also take a little cue from this and thus make maintenance easier.


The fire connector is made of aluminum and brass. The quality of the aluminum casting significantly affects the pressure resistance of the connector. A mixture that is too porous will cause the nail of the connector to break. For this reason, it should be ensured that the connector meets the SFS 3798 standard set for it. The claws are the connector's weak point. When it breaks, the pressurized hose becomes a whip!


This is exactly the connector that can be found in apartment buildings. It is usually placed on an outside wall or stairwell. If necessary, firefighters can take extinguishing water directly from the apartment building's fire hydrant with their own hoses.


The fire connector is first and foremost a claw connector. You can check the size of the connector by measuring the gap between the nails on the connector. For example, in a 2-inch fire connector, the nail spacing is 68 mm. There is a good table in our catalog that shows the connector sizes and nail spacing. The Gost connector, which is rare in Finland, looks very similar to our fire connector.


When used correctly, the connector is a perfectly functional solution, for example, in submersible pumps and other water transfers under 10 bar. The connector is well suited for suction and pressure. Due to its lightness, it is nice and easy to handle. At high pressures and pressure shocks, the connector becomes a safety risk.


Big thumbs up from the hose master for this connector because it has a male and a female in one. The connector always fits, as long as the nail spacing is correct.

Author

Toni Mielikainen
CEO
Mittaletku
+358 400 292 874
[email protected]
Linkedin

Toni is perhaps Finland's most experienced hose master, whose hands have passed through hundreds of solutions for all domestic industries. More than 20 years of experience in hose and connector matters can be seen as expertise that both large production plants and small breweries benefit from.

Porvoo measuring tape Toni Mielikäinen

Author

Toni Mielikainen
CEO
Mittaletku
+358 400 292 874
[email protected]
Linkedin

Toni is perhaps Finland's most experienced hose master, whose hands have passed through hundreds of solutions for all domestic industries. More than 20 years of experience in hose and connector matters can be seen as expertise that both large production plants and small breweries benefit from.

Porvoo measuring tape Toni Mielikäinen

Author

Porvoo measuring tape Toni Mielikäinen

Toni Mielikainen
CEO
Mittaletku
+358 400 292 874
[email protected]
Linkedin

Toni is perhaps Finland's most experienced hose master, whose hands have passed through hundreds of solutions for all domestic industries. More than 20 years of experience in hose and connector matters can be seen as expertise that both large production plants and small breweries benefit from.

We used these products